Electrical installation test report as PDF: IR, Zs, RCD, earthing. Offline.
UZYTAK Pomiary turns the readings of any installation tester into a clear test report. Type the values in — the app compares them with the criteria at once, shows pass or fail and prints a PDF ready to sign.
For qualified electricians and small electrical firms: initial verification, periodic inspection and tests after repair or alteration.
No ads, no account, no subscription. Works with every tester — readings are typed in by hand, not tied to one brand.
TESTS IN THE REPORT
• Continuity of protective and bonding conductors: R ≤ Rmax
• Insulation resistance: single- and three-phase circuits, L-N, L-PE, N-PE (L1-L2 … N-PE), test voltage and minimum per HD 60364-6 table 6.1 (SELV/PELV 250 V ≥ 0.5 MΩ, up to 500 V 500 V ≥ 1.0 MΩ, above 500 V 1000 V ≥ 1.0 MΩ), ">999" above the range
• Fault loop impedance Zs: circuit breakers B, C, D (Ia = 5, 10, 20 × In), gG fuses (5 s per IEC 60269-1), RCD or your own Ia; Za = U0 / Ia, fault current Ik, optional 2/3 factor
• RCD tests (AC, A, F, B, also selective S): trip time at IΔn and 5 × IΔn, trip current IA, touch voltage UB, test button
• Earthing resistance: your own limit or RA ≤ UL / IΔn in TT systems
FAST ON SITE
• "Save and add next" — next circuit with the same protective device, the circuit number counts up by itself
• The result shows while you type, every criterion separately
• TN-S, TN-C, TN-C-S, TT, IT; U0 and UL adjustable
PDF REPORT
• Installation, client, date, next test date, standards (editable)
• Instruments: make and model, serial number, calibration date
• Inspector: name, qualification certificate, company
• Result tables with the criterion under each table, visual inspection remarks, conclusions and overall result
• Report language independent of the app language
FREE AND PRO
• Free: up to 3 reports with every test, assessment and PDF
• Pro, one payment: unlimited reports, signature and company stamp on the PDF, copy of a report for the next periodic inspection (same circuits, empty readings), CSV export, backup
YOUR DATA STAYS ON THE PHONE
• Reports, addresses, signatures and stamps are stored only on the phone. Works offline, no analytics, no tracking
IMPORTANT
The app is a report template and a calculator. The qualified person who carries out the tests is responsible for the measurements, their assessment and the signed report. The criteria are printed under each table — check them against the standards and regulations that apply to your installation. The report follows IEC / HD 60364-6, not a national certificate form (e.g. BS 7671 EICR).
21 languages: Afrikaans, Čeština, Dansk, Deutsch, English, Español, Français, Italiano, Magyar, Nederlands, Norsk, Polski, Português, Română, Slovenčina, Suomi, Svenska, Türkçe, Русский, Українська, 日本語.
Questions:
[email protected] · uzytak.com
First release: test records for insulation, Zs, RCD, continuity and earthing, PDF protocol, 21 languages.